EPS F 70

100% recyclable - circular economy.

Purpose: TERRASIT EPS F 70 expanded polystyrene facade panels are used for thermal insulation in ETICS facade systems in accordance with EAD (European assessment document) 040083-00-0404. The panels are installed with facade adhesives and additional mechanical fixation. During installation, we must adhere to the project and installation instructions for the facade system, applicable legal regulations, and professional rules. The product complies with BAS EN 13163. Class E, reaction to fire, in accordance with BAS EN 13501-1 (self-extinguishing).

EPS-EN 13163-L(2)-W(2)-T(2)-S(2)-P(5)-DS(N)2-DS(70,-)1-TR100-BS100-WL(T)2.5

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±2 [mm]
Flatness
±5 [mm]
Thermal conductivity : λD
0.039 [W/mK]
Fire reaction
Class E
Tensile strength
100 [kPa]
Flexural strength
100 [kPa]
Water absorption
2,5 [%]
Dimensional stability
±0.2 [%]
Dimensional stability on 70°C
≤1 [%]
Water vapor diffusion resistance, µ
20-60

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,24
0,49
0,73
0,98
1,22
1,46
1,95
2,44
2,93
3,41
3,66
3,90
4,39
4,88
5,37
5,85
6,10
7,32
logo_terrasit_bs_blue

EPS F Classic 80​

100% recyclable - circular economy.

Purpose: TERRASIT EPS F CLASSIC expanded polystyrene facade boards are used for thermal insulation in ETICS facade systems in accordance with European assessment document (EAD) 040083-00-0404. The boards are installed using facade adhesives or additional mechanical fastenings. During installation, the project and installation instructions for the facade system, as well as applicable legal regulations and professional rules, must be followed. A life cycle assessment (LCA) of the product is conducted. The product also has an environmental product declaration (EPD), in accordance with EN 15804:2012+A2:2019. The product complies with BAS EN 13163, with a Class E fire reaction, according to BAS EN 13501-1 (self-extinguishing).

E EPS-EN 13163-L(2)-W(2)-T(2)-S(2)-P(5)-DS(N)2-DS(70,-)1-TR150-BS115-WL(T)4,5.

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±2 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.038 [W/mK]
Fire reaction
Class E
Tensile strength
150 [kPa]
Flexural strength
115 [kPa]
Water absorption
4,5 [%]
Dimensional stability
±0.2 [%]
Dimensional stability on 70°C
≤1 [%]
Water vapor diffusion resistance, µ
20-70

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,26
0,53
0,79
1,05
1,32
1,58
2,11
2,63
3,16
3,68
3,95
4,21
4,74
5,26
5,79
6,32
6,58
7,89

EPS F Super 100

100% recyclable - circular economy.

Purpose: TERRASIT EPS F SUPER expanded polystyrene facade boards are used for thermal insulation in ETICS facade systems in accordance with EAD (European assessment document) 040083-00-0404. Boards are installed with facade adhesives or additional mechanical fixation. During installation, we must follow the project and instructions for the installation of the facade system, applicable legal regulations, and professional rules.

EPS-EN 13163-L(2)-W(2)-T(1)-S(2)-P(5)-DS(N)2-DS(70,-)1-TR150-BS115-WL(T)4,5.

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±2 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.037 [W/mK]
Fire reaction
Class E
Tensile strength
150 [kPa]
Flexural strength
115 [kPa]
Water absorption
4,5 [%]
Dimensional stability
±0.2 [%]
Dimensional stability on 70°C
≤1 [%]
Water vapor diffusion resistance, µ
20-70

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,27
0,54
0,81
1,08
1,35
1,62
2,16
2,70
3,24
3,78
4,05
4,32
4,86
5,41
5,95
6,49
6,76
8,11
logo_terrasit_bs_blue

EPS F Professional

100% recyclable - circular economy.

Purpose: TERRASIT EPS F PROFESSIONAL expanded polystyrene facade panels are used for thermal insulation in ETICS facade systems in accordance with EAD (European assessment document) 040083-00-0404. The panel is installed using facade adhesives or additional mechanical fastening. During installation, we must adhere to the project and installation instructions for the facade system, as well as applicable legal regulations and professional rules. Product life cycle analysis (LCA – Life cycle assessment). Environmental product declaration (EPD). In accordance with EN 15804:2012+A2:2019 requirements. The product complies with BAS EN 13163. Class E, fire reactions, in accordance with BAS EN 13501-1 (self-extinguishing).

EPS-EN 13163-L(2)-W(2)-T(1)-S(2)-P(5)-SS90-CS(10)80-DS(N)2-TR150-WL(T)3.

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±2 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.036 [W/mK]
Fire reaction
Class E
Tensile strength
150 [kPa]
Flexural strength
80 [kPa]
Water absorption
0,04[kg/m2]
Dimensional stability
3,0 [%]
Dimensional stability on 70°C
±0.2 [%]
Water vapor diffusion resistance, µ
20-40

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,28
0,56
0,83
1,11
1,39
1,67
2,22
2,78
3,33
3,89
4,17
4,44
5,00
5,56
6,11
6,67
6,94
8,33
logo_terrasit_bs_blue

EPS F Grafit

100% recyclable - circular economy.

The TERRASIT EPS F GRAPHITE thermal insulation is designed for use in ETICS facade systems to provide increased thermal power in EPS panels. This product is certified by EAD (European Assessment Document) 040083-00-0404, and can be installed using facade adhesives or additional mechanical fastenings. When installing TERRASIT EPS F GRAPHITE, it is important to follow project and installation instructions for the facade system, comply with legal regulations, and adhere to professional rules. The product has undergone a Lifecycle Assessment (LCA) and has an Environmental Product Declaration (EPD) compliant with EN 15804:2012+A2:2019. TERRASIT EPS F GRAPHITE complies with BAS EN 13163 and is classified as E for fire reactions in accordance with BAS EN 13501-1, making it self-extinguishing.

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±2 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.031 [W/mK]
Fire reaction
Class E
Tensile strength
150 [kPa]
Flexural strength
150 [kPa]
Water absorption
2,5 [%]
Dimensional stability
±0.2 [%
Dimensional stability on 70°C
≤1 [%]
Water vapor diffusion resistance, µ
20-70

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,31
0,63
0,94
1,25
1,56
1,88
2,50
3,13
3,75
4,38
4,69
5,00
5,63
6,25
6,88
7,50
7,81
9,38
logo_terrasit_bs_blue
Graphite R with recycled material - Nature star

100% recyclable - circular economy.

Purpose: We use TERRASIT EPS F GRAPHITE thermal insulation for facade EPS panels with increased thermal power in ETICS facade systems, according to the European assessment document (EAD) 040083-00-0404. We install panels with facade adhesives and additional mechanical fastening, adhering to project and installation instructions, valid legal regulations, and professional rules. The product undergoes life cycle assessment (LCA) and environmental product declaration (EPD) in compliance with EN 15804:2012+A2:2019 requirements. The product is also in compliance with BAS EN 13163, Class E, fire reaction, and self-extinguishing according to BAS EN 13501-1.

EPS-EN 13163-L(2)-W(2)-T(1)-S(2)-P(5)-SS60-CS(10)70-DS(N)2-TR100-WL(T)2.

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±1 [mm]
Rectangularity
±2 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.031 [W/mK]
Fire reaction
Class E
Tensile strength
100 [kPa]
Tensile strength (10%)
70 [kPa]
Flexural strength
60 [kPa]
Short-term water absorption (partial immersion)
0,1[kg/m2 ]
Water absorption (total immersion)
2,0 [%]
Dimensional stability
±0.2 [%]
Water vapor diffusion resistance, µ
20-40

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,31
0,63
0,94
1,25
1,56
1,88
2,50
3,13
3,75
4,38
4,69
5,00
5,63
6,25
6,88
7,50
7,81
9,38

EPS 100

100% recyclable - circular economy.

Purpose: Cut expanded polystyrene boards TERRASIT EPS 100 are used for thermal insulation of floors, flat roofs, attics, underfloor heating, and cold storage. The boards are installed by glueing, mechanical fastening, or free laying, depending on their intended use. Installation must be carried out following the installation instructions, applicable laws, and industry rules. The product complies with BAS EN 13163. Class E, fire reaction, in accordance with BAS EN 13501-1 (self-extinguishing).

EPS-EN 13163-L(2)-W(2)-T(2)-S(5)-P(5)-DS(N)5-DS(70,-)3-CS(10)100-WL(T)4.

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±5 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.036 [W/mK]
Fire reaction
Class E
Tensile strength (10%)
100 [kPa]
Water absorption
4 [%]
Dimensional stability
2,0 [%]
Dimensional stability on 70°C
≤3 [%]

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,28
0,56
0,83
1,11
1,39
1,67
2,22
2,78
3,33
3,89
4,17
4,44
5,00
5,56
6,11
6,67
6,94
8,33

EPS 150

100% recyclable - circular economy.

Purpose: Cut expanded polystyrene boards TERRASIT EPS 150 are used for thermal insulation of flat roofs (higher loads, walkable and service surfaces), floors with thicker insulation, floors with higher loads, and insulation of cold attics with occasional walkable surface. The boards are installed by sticking, mechanical fixing, or free laying, taking into account the use instructions, applicable legal regulations, and professional standards. The product is in accordance with BAS EN 13163. Class E, reaction to fire, in accordance with BAS EN 13501-1 (self-extinguishing).

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±5 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.036 [W/mK]
Fire reaction
Class E
Compressive strength (10%)
150 [kPa]
Water absorption
4 [%]
Dimensional stability
±0.5 [%]
Dimensional stability on 70°C
≤3 [%]

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,28
0,56
0,83
1,11
1,39
1,67
2,22
2,78
3,33
3,89
4,17
4,44
5,00
5,56
6,11
6,67
6,94
8,33

EPS 200

100% recyclable - circular economy.

Purpose: TERRASIT EPS 200 expanded polystyrene boards are used for thermal insulation of flat roofs (higher loads, walkable and serviceable surfaces), floors with higher thicknesses of thermal insulation, floors with higher loads, and insulation of cold attics with occasional walkable surfaces. The boards are installed by adhesive bonding, mechanical fixing, or free laying, depending on the intended use. During installation, the installation instructions, applicable legal regulations, and professional rules must be followed. The product is in accordance with BAS EN 13163. Class E, fire reactions, in accordance with BAS EN 13501-1 (self-extinguishing).

Characteristics
Performance
Dimensions
1000x500xd [mm]
Length
±2 [mm]
Width
±2 [mm]
Thickness
±2 [mm]
Rectangularity
±5 [mm]
Flatness
±5 [mm]
Thermal conductivity: λD
0.034 [W/mK]
Fire reaction
Class E
Compressive strength (10%)
200 [kPa]
Water absorption
4 [%]
Dimensional stability
±0.5 [%]
Dimensional stability on 70°C
≤3 [%]

Coordinated technical specification

EN 13163:2012 + A1:2015

Thermal resistance by thickness in mm - RD[m2 K/W]
10
20
30
40
50
60
80
100
120
140
150
160
180
200
220
240
250
300
0,28
0,56
0,83
1,11
1,39
1,67
2,22
2,78
3,33
3,89
4,17
4,44
5,00
5,56
6,11
6,67
6,94
8,33

XPS NL

Purpose: XPS insulation boards with a thermal conductivity (λD) of 0.034 W/mK made from extruded polystyrene, with a compressive strength of 300 kPa and a rough surface (structure “waffle”), and with edges with stepped overlap, are designed for installation by adhesive bonding and concrete pouring, as well as for direct application of adhesives, plaster, or other coatings. They are primarily intended for: thermal insulation in flat roofs with high mechanical loads, thermal insulation of floors with high mechanical loads, and thermal insulation of external walls of buildings that are backfilled.

Sloping boards

Sloped boards are used to create slopes in flat roof systems for the smooth drainage of rainwater. Possible slopes are 0.5%, 1%, 1.5%, 2%, and 3%, etc. and possible pressure strength ranges from 70-200 kPa. They can be ordered to specification.