TERRASIT EPS 150 panels are used for flat roofs requiring higher compressive loads (walkways, service areas). Panels are installed using mechanical fastening or free installation. When installing, instructions must be followed to avoid unnecessary damage, and achieve maximum insulating power.
The product is in accordance with BAS EN 13163. Class E, reaction to fire, in accordance with BAS EN 13501-1 (Self-extinguishing).
EPS-EN 13163-L(3)-W(3)-T(2)-S(5)-P(5)-BS200-CS(10)150-DS(N)5 DS(70,-)3

DOWNLOAD Terrasit EPS 150 (technical specifications)
Properties of Terrasit EPS 150 | EPS EN | Test method EN | Value/Class | Standardized technical specification | |||||||||||||
Dimensions | – | 822 | 1000x500xd mm | BAS EN ISO 13163 +A2:2018EN 13163:2015HRN EN 13163:2015 | |||||||||||||
Length | L | 822 | ± 2 mm | ||||||||||||||
Width | W | 822 | ± 2 mm | ||||||||||||||
Thickness | T | 823 | ± 1 mm | ||||||||||||||
Squareness | S | 824 | ± 2 mm | ||||||||||||||
Flatness | P | 825 | ± 5 mm | ||||||||||||||
Thermal conductivity (λ D) | – | 12667 | 0,036 W/mK | ||||||||||||||
Fuel Classification EN 13501 | – | 13501-1 | Class E | ||||||||||||||
Compressive stress at 10% deformation | CS(10) | 150 kPa | |||||||||||||||
Long-lasting water absorption during immersion | WL | 12087 | 4 % | ||||||||||||||
Stability of changes under lab conditions | DS(N) | 1603 | ± 0,5 % | ||||||||||||||
Stability of changes under certain conditions | DS(70-1) | 1604 | ≤ 3 % | ||||||||||||||
EPS-EN 13163-L2-W2-T2-S2-P5-BS115-CS(10)80-DS(N)5-DS(70,-)3-WL(T)4 | |||||||||||||||||
Thermal resistance by thickness in mm – RD[m2K/W] | |||||||||||||||||
10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 140 | 150 | 160 | 180 | 200 | 220 | 240 | 250 | 300 |
0,28 | 0,56 | 0,83 | 1,11 | 1,39 | 1,67 | 2,22 | 2,78 | 3,33 | 3,89 | 4,17 | 4,44 | 5,00 | 5,56 | 6,11 | 6,67 | 6,94 | 8,33 |